More Products From This Vendor
Bently Nevada 3500/05-01-01-05-00-01 System Rack
Bently Nevada 3500/05-01-01-05-00-01 full-size 19-inch panel mount instrument rack chassis with ATEX/CSA multi-approvals and CE compliance. Brand New factory stock.
Description
The Bently Nevada 3500/05-01-01-05-00-01, also cataloged as the 3500/05 CE Compliant Multi-Approval Chassis, operates as a dedicated hardware component for high-speed backplane data communication and distributive DC power allocation within the 3500 Machinery Protection System. This specific full-size unit incorporates specialized manufacturing specifications that enable installation across global regions demanding combined North American and European hazardous area compliance markings. It establishes the multi-channel electronic motherboard framework required to execute real-time machine safety voting logic across critical industrial turbomachinery platforms.
Suffix Breakdown & Model Matrix
This exact hardware configuration conforms to the following structural factory option selections:
- 01 (Rack Size Option): Designates a 19-inch EIA Full-Size Rack layout containing 14 operational instrumentation slots alongside two dedicated leftmost power supply slots.
- 01 (Mounting Option): Configures the physical structure for a Panel Mount setup, utilizing external mounting clamps to fasten the chassis securely into a rectangular instrument panel cutout.
- 05 (Agency Approval Option): Selects the Multi-Approvals configuration, combining North American (CSA/NRTL/C Class I Division 2) and European/International (ATEX/IECEx Zone 2) hazardous area protection standards.
- 00 (Reserved Option): Factory default reserved parameter containing no special field modifications or custom additions.
- 01 (European Compliance Option): Specifies full CE compliance integration, adding localized protective components and specific post-production regional marking kits.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | 3500/05-01-01-05-00-01 |
| Brand | Bently Nevada |
| Origin | United States |
| Weight | 7.50 kg (Chassis assembly base weight) |
| Dimensions | 482.60 mm x 265.94 mm x 246.38 mm |
| Operating Temp | -20 to +65 deg C |
| Power Consumption | Passive multi-layer backplane; actual power distribution determined by active modular load |
| Layout Type | 19-inch EIA industrial footprint with specialized rear I/O access |
| Structural Capacity | 2 Power supply positions + 14 variable instrumentation slots |
| Electrical Standards | Full CE compliance marking with integrated electromagnetic shield mitigation |
Rotor Dynamics and Eddy-Current Probe Scaling
The multi-layer backplane circuitry embedded within this specific chassis layout enforces strict physical trace shielding boundaries to maximize cross-talk suppression. These internal ground planes prevent high-frequency oscillator signals from bleeding between adjacent radial vibration monitor cards. By containing electromagnetic interference, the backplane maintains a precise loop environment to validate gap voltage validation (-10 VDC targets) across 3300 XL proximity sensor circuits, preserving raw waveform data fidelity for advanced rotor dynamics diagnostic software.
Frequently Asked Questions
Q: How do the international hazardous area certifications affect module swap-out procedures on this specific rack model?
A: The -05 multi-approval selection dictates that while the physical backplane architecture supports hot-swapping due to staggered electrical contact pin lengths, local plant safety personnel must verify that the atmosphere is completely non-hazardous or issue a hot-work permit before executing live module removal or insertion in Zone 2 / Division 2 environments.
Q: What items are included with the -01 European Compliance option pack on this panel mount model?
A: The -01 option provides verified CE compliance hardware, which includes integrated grounding modifications, specific electromagnetic shielding covers for the rear input/output terminal arrays, and direct structural grounding enhancement kits required to pass formal European EMC and Low Voltage directives.
Field Installation Guidelines
- Shielding and Grounding Standards: Secure a heavy-gauge copper grounding strap from the primary rack earth stud directly to the plant instrumentation master ground. Terminate all incoming eddy-current probe shield drain wires at the rear terminal block ground screws to avoid noise injection into the backplane.
- Panel Cutout Tolerances: Ensure the rectangular panel mounting cutout adheres strictly to the factory specified dimensional boundary limits. Use all provided side-mounting retention clamps to secure a rigid mechanical seal, minimizing localized structural resonance from transferring onto the internal monitor cards.
- Power Trace Isolation: Route primary AC or high-voltage DC supply line conduit separately from the low-voltage sensor input wiring trays. This separate routing method minimizes external induced magnetic fields from corrupting low-level vibration signals.
Additional information
| Weight | 7.5 kg |
|---|---|
| Dimensions | 620 × 320 × 500 mm |
Recently Viewed Items

Emerson DeltaV Right-Side Localbus Extender KJ4010X1-BG1 12P0830X072
$99.00Rated 0 out of 50 reviews$199.00Available: 99 Sold: 0
Allen-Bradley 1756-IV16 | 16-Point 10-30V DC ControlLogix Input Card
$99.00Rated 0 out of 50 reviews$199.00Available: 99 Sold: 0
1761-NET-AIC Allen-Bradley | RS-232 to RS-485 AIC+ Communication Link
$99.00Rated 0 out of 50 reviews$199.00Available: 99 Sold: 0
Allen-Bradley ControlLogix 1756-SIM | Virtual Chassis Input/Output Simulator
$99.00Rated 0 out of 50 reviews$199.00Available: 99 Sold: 0
1769-L36ERM Allen-Bradley | 16-Axis Integrated Motion PLC Processor
$99.00Rated 0 out of 50 reviews$199.00Available: 99 Sold: 0
merson DeltaV SIS KJ2201X1-JA1 | 12P3323X042 Redundant I/O Terminal Block
$99.00Rated 0 out of 50 reviews$199.00Available: 99 Sold: 0
























0.0 Average Rating Rated (0 Reviews)